All calculators
26 calculators, grouped by the job they do. Every one is free, with no login and no watermark on the PDF.
Core Calculations
Essential tools for every job- Cable SizingAS/NZS 3008.1.1:2025Auto-size cables for current rating, voltage drop, and earth fault loop impedance.
- Voltage DropAS/NZS 3008.1.1:2025Check voltage drop compliance for any cable size, length, and load.
- Maximum DemandAS/NZS 3000:2018Calculate maximum demand using Tables C1 and C2 for residential and commercial.
- Conduit FillAS/NZS 3000 Tables C10 to C12Check cable fill percentage and find the minimum conduit size.
- Earth ConductorAS/NZS 3000:2018Size earth conductors using Table 5.1 or the adiabatic equation.
- Circuit BreakerAS/NZS 3000:2018Select the correct breaker rating and curve for any circuit.
Protection & Safety
Safety-critical calculations- Arc FlashIEEE 1584:2018Incident energy, arc flash boundary, and PPE category.
- Earthing SystemAS/NZS 3000 S5Design earth electrodes with touch and step voltage checks.
- RCD SelectionAS/NZS 3000:2018Select the right RCD type and sensitivity. Includes NZ Type A mandate.
- IDMT RelayIEC 60255Operating time for all 5 IEC inverse curves.
- Emergency LightingAS/NZS 2293.1Luminaire count, exit signs, spacing, and battery sizing.
Solar & EV
Renewables and electric vehicles- Solar PV SizingAS/NZS 4777.2 + 5033Full solar system sizing covering panels, inverter, yield, payback, and export limits.
- Voltage RiseAS/NZS 4777.1:2024Solar PV voltage rise and export limit calculation for grid-connected inverters.
- EV Charger SizingAS/NZS 3000 + 3001.1Cable and breaker sizing for EV charger installations.
Motors & Power
Industrial and commercial- Motor CalculatorAS/NZS 3000 + 1359Full load current, cable sizing, breaker selection, and starter sizing.
- Three-Phase PowerUtilityConvert between voltage, current, and power for star and delta systems.
- Full Load CurrentAS/NZS 3000 + 3008Calculate FLC for motors, transformers, heaters, and lighting.
- Motor SpeedIEC 60034Synchronous and actual speed for any pole count and frequency.
- Motor TorqueAS/NZS 1359 + IEC 60034Full load, starting, breakdown, and pull-up torque calculations.
- Power FactorAS/NZS 61000.3.100Calculate capacitor bank size to correct power factor.
Transformers & Generators
Sizing and fault analysis- Transformer SizingAS 2374 / AS 60076Size transformers with demand factors, growth planning, and protection.
- Transformer FaultIEC 60909Three-phase, phase-to-phase and earth fault current at the transformer secondary.
- Generator SizingAS/NZS 3010Size generators for motor starting, derating, and fuel consumption.
- Generator Fault CurrentIEC 60909-0Sub-transient, transient and sustained fault current, and whether the MCB trips on generator supply.